Level Based


 

Maintenance Free, Level based

Water Pump Controller

Ensures pumping of  water  by automatically switching on the pump at preset lEVEL and switching off if sump level is low ( with retry ) / overhead tank is full /
lapse of pumping duration


        FEATURES

  •     Activation at preset water level

  •     Water Level Indicator ( 4 stage )   

  •     User friendly menu selection

  •     User settable Pumping parameters i.e. Activation level, Priming, Pumping
        Duration etc.

  •     Retains settings in the absence of power 

  •     Protection against dry running  of pump

  •     Prevents overflow from tank

  •     Pumping & Tank / Process status reporting on backlit LCD + Audible signals

  •     On line Sensor Check 

  •     Easy installation ( doesn't require plumbing )

  •     Sensors don't require any maintenance

  •     Saves water & electricity

  •     Suitable for Underground tank / Ground water pumps


Process of Pump Control

  •     Set the activation level ( 1/4, 1/2 or 3/4)
     

  •     Pump is switched on when the O/H tank level falls below the activation level
     

  •     If the Sump has water
     

    •     Priming is done for 2 minutes
       

      •     If water is not available at the tank inlet, pump is switched off + audio alarm
         

      •     Else if water is available, pumping continues till any of the conditions are met

        •     Tank full or

        •     Max. pumping time of 60 min. is over or

        •     Sump goes dry
           

  •     Else if Sump is dry then it shall retry @ 60 min. till the time sump has water
     

Back Home Up Next