Logger Specifications


 

SPECIFICATIONS -

1.   No. of Input Channels                    -     7

2.   Input Type & Range                       -     Single Ended 20 VDC, protection against reverse connection                                                                   +10 °C  to  + 50 °C for ambient Temp. ( measurement through                                                                   inbuilt sensor ).

3.   Display                                           -     16 x 2 Alphanumeric LCD.

4.   Resolution                                     -     0.1 V for voltage input & 1 °C for ambient temperature

5.   Logger Operation                          -     via 3 tactile switches thru a user friendly menu

6.   Logger Parameters                        -     are programmed thru the software supplied alongwith,                                                                   from the PC. The programmable parameters are

                                                                  #    Logger ID

                                                                  #    Programmed Status ( Yes / No )

                                                                  #    Data Logged ( Yes, if complete laps are logged / No, if                                                                                               logging is incomplete )

                                                                  #    Downloaded Status ( Yes if data has been downloaded                                                                                                        into the PC / No )

                                                                  #    Channels ( 1 to 7 )

                                                                  #    No. of Laps ( 1 to 99 )

                                                                  #    Logging @ 1 to 99 sec. / min. / hr.

                                                                  #    Laps Logged

                                                                  #    Low & High Voltage Limits

                                                                  #    Start Time & Date of Test

                                                                  #    Name of Test

                                                                  #    Vendor Names

                                                                  #    Logged Data

7.   PC Connectivity                                   -     RS 232 Serial Port

8.   Power Supply                                      -     6 VDC through battery or AC adapter

9.   Consumption                                       -     1 W ( max.)

10.  Size                                                     -     6” ( L ) x 4” ( W ) x 1¾” ( H )

11.  Scope                                                  -     Once programmed the logger becomes a self contained
                                                                        
independent unit, capable of displaying all the programmed
                                                                         parameters & logged data on its 16 x 2 alphanumeric LCD
                                                                         viz. No. of channels to be used, Vendor names whose batteries
                                                                         have to be connected at the various channels, Start date & time
                                                                         of test, Name of test to be conducted etc.

                                                                         The real time logging status is displayed once the process
                                                                         is initiated.

                                                                        In case of abnormal termination, logging is resumed from the
                                                                        lap no. where it left.

                                                                        There can be a number of such loggers in use, since each
                                                                        Logger is assigned a unique ID No.

 12.   System requirement                             -  Pentium 100 MHz, 24 MB RAM, 10 MB free disk space, Color 
                                                                        monitor, CD-ROM drive, Windows 95 or higher operating system. 

 