Maintenance Free, Real Time / Inflow based
Water Pump Controller with Level
Indicator Ensures
pumping of water by automatically switching ON the pump at
Preset Timings
OR
Whenever Water comes in the supply line
and switching off when
water is not available ( after retry ) / overhead tank is full /
lapse of pumping duration
FEATURES
-
User selectable Real Time / Inflow Based Pump Activation
-
Water
Level Indicator ( 4 stage )
-
In Built
Electronic Clock ( 24 Hr. format ) with Alarm
-
User
settable 8 Pump Time settings
-
User
friendly menu selection
-
User
settable Pumping parameters i.e. No. of Retry attempts, Priming, Pumping
Duration etc.
-
Internal Battery backup
-
Protection against dry running of pump
-
Prevents overflow from tank
-
Pumping & Tank / Process status reporting on backlit LCD + Audible signals
-
On
line Sensor Check
-
Generates report for last Pumping Action
-
Easy
installation
-
Sensors don't require any maintenance
-
Saves
water & electricity
-
Suitable for Online Pumping
Process
of Pump Control
Pump can be
controlled thru the
1. Water
flow at the O / H Tank Inlet
OR
2. Level
in the Sump
1.
The Pump Operating Logic ( w.r.t. water
flow at the O / H Tank Inlet ) is
-
Select
the method of Pump Control - Time* or Inflow^
-
*Set Real Time
and Pump ON timings (max. 8 settings) as per instructions
-
*Pump
is
switched ON
at
preset time OR
^Whenever Water comes in the supply line
-
Priming is done
for 2 minutes
-
If water is
available at tank inlet, then pumping continues till any of
the following conditions are met
-
Tank
Full - Pumping stops and TANK FULL is displayed
-
Max.
pumping time of 60 min. is over & pumping stops. TANK
???? is displayed.
-
While
pumping, if water supply stops then it shall retry 2 times at an
interval of 8 min. ( 2 min. priming + 6 min. wait ) In case water
is still not available then pumping stops and TANK ???? is
displayed.
-
Manually stopped through SPI, PUMPING ABORTED is displayed and
pump stops.
-
If water is
not available it shall retry 9 times at an interval of 8 min. ( 2 min.
priming + 6 min. wait ). In case all nine attempts fail then INLET DRY
message is displayed.
2.
The Pump Operating Logic ( w.r.t. water
level in the Sump ) is
Having set the Pump On timings, the pump is switched on at
preset time & continues, irrespective of the flow of water at the tank inlet
but subject to availibility of water in the Sump, till the
-
max. pumping
duration is over or
-
the tank is
full or
-
manually
stopped thru S.P.I. or
-
level
goes down in the sump.
|